What Temp Hi 12H+
actually means.
Temp Hi 12H+ is the longer version of the warm alert on a 3000 Series beverage center. Half a day that far above the setting usually means the unit is not removing heat, so the service steps move from the door to the evaporator fan and the sealed system.
U-Line beverage center display · also shown as L Temp Hi 12H+, R Temp Hi 12H+
What to do when Temp Hi 12H+ shows on the beverage centerKind of codeTemperature and alarms
The unit is warning that the cabinet has drifted away from its setting: too warm after a long power cut, a restock of room-temperature cases or a door propped open while guests came and went, or too cold near the point where cans start to freeze. Often it settles by itself once the door stays shut; a warning that keeps returning with the door closed points to the sensor, the fan or the cooling behind it.
Usually leads toBeverage center thermostat and sensor repair
Finding and replacing the dial thermostat or electronic sensor that tells a beverage center when to cool, so cans stay cold without freezing and splitting.
Shows up asReading a Beverage Center Error Code
A beverage center error code may be two or three characters on the temperature readout, a number blinking where the setting used to sit, a string of dashes, or a small icon pulsing beside a beep, and it can appear while every can on the shelves is still ice cold.
MakeU-Line
U-Line beverage centers repaired where they are fitted, with the glass door and seal checked early.
SourceU-Line 3036BVWC 36-inch beverage center user guide and service manual (3000 Series)
3000 Series beverage centers with the scrolling text display, such as the 36-inch 3036BVWC. On a two-zone model the message starts with L or R for the left or right side; a single-zone model shows it without the letter.
Before you book,
in this order.
Each step comes from U-Line's own guidance for Temp Hi 12H+ on its beverage centers. Follow it to the end: the last card says whether this is a visit.
Close the door, clear the front grille and give the unit an hour.
Move anything that must stay cold into another refrigerator.
Book a visit and mention how long the message has been showing.
Still there?
It usually turns into beverage center thermostat and sensor repair. Book with the code and the model number.
What not to do
Temp Hi 12H+ is not a reason to lower the set point; the unit is already failing to reach the one it has. It also does not point at a sensor, since sensor trouble has its own open and short messages.
What you may
notice with it.
The beverage center problems Temp Hi 12H+ tends to arrive with. Answer these at the beverage center before anyone is booked.
All problemsWhere Temp Hi 12H+ usually leads
Beverage center thermostat and sensor repair.
U-Line
beverage centers.
U-Line beverage centers repaired where they are fitted, with the glass door and seal checked early.
U-Line beverage center repairMore U-Line codes
Temperature and alarms on other makes
Undercounter beverage center
A glass-door cabinet for cans and bottles, set in under a counter in a wet bar, a basement bar, a game room or at the end of a kitchen island, and breathing only through the grille at its toe kick.
Freestanding beverage cooler
A glass-door beverage cooler that stands on its own against a wall, in a game room, a home office, a garage or on a counter, and sheds heat through its back or sides rather than a front grille.
Outdoor beverage center
A beverage center rated by its maker for outdoor use, built under a covered patio counter or a poolside bar, sealed against weather and plugged into a GFCI-protected outlet.
In U-Line's own words
Left or right zone temperature +10° over set point for over 12 hours.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. 3000 Series beverage centers with the scrolling text display, such as the 36-inch 3036BVWC. On a two-zone model the message starts with L or R for the left or right side; a single-zone model shows it without the letter.
U-Line Temp Hi 12H+ beverage center repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about Temp Hi 12H+.
Can I clear Temp Hi 12H+ myself?
Is Temp Hi 12H+ on a U-Line worse than Temp Hi 6H+?
Can I clear Temp Hi 12H+ on my U-Line by unplugging it?
Why is only one side of my two-zone U-Line showing Temp Hi 12H+?
Back to your everyday
Still showing Temp Hi 12H+?
Put three things in the booking: the characters or blinks exactly as shown, the model number in full, and whether a can from the middle shelf is still cold. With those, the technician arrives already half way to the answer.